Test Products International

Clamp-on Meters (Current)

 

 

 

 


All TPI Clamp-on Meters have a 3-year limited warranty

TPI offers a full line of digital clamp-on meters for electrical, commercial, HVAC/R, industrial, and process control applications.

Model

Measurement
Range

Feature/Benefits

Additional
Info

265:

AC Amps    
... 400
Frequency  
... 40 MHz
Capacitance
... 4,000 uF
AC Volts
...
600       
DC Volts
... 600
Resistance
...40 Meg Ohm
Basic DC accuracy
...
0.5%
  • Slim jaw and body design for use is crowded electrical panels.
  • Capacitance up to 4,000 micro-farads
  • Frequency
  • Up to 400 AC amps with 0.01 resolution
  • AC/DC volts up to 600
  • 0.1 DC millivolt resolution
  • Diode, resistance, and audible continuity
  • CAT III 600V rated
  • cULus 61010
  • 3-year limited warranty

Product Sheet

 

Instruction manual

 

Specifications

 

Applications

 

FAQs

 

270:

AC Amps     
...400
Frequency    
...400 MHz
Capacitance  
...4,000 uF
Temperature
...1,000 F
AC Volts     
... 600
DC Volts
...600       
Resistance  
... 40 Meg Ohm
Basic DC accuracy
... 0.5%
  • True RMS 400 A AC
  • Measure motor in-rush current and run current
  • Measure temperature differential with relative mode
  • Frequency, Min/Max/Record, Data Hold, and Peak Hold
  • Up to 40,000 microfarads to test start and run capacitors
  • 4,000 count display with 41 segment analog bar graph
  • CAT III 600V rated
  • cULus 61010
  • 3-year limited warranty

Product Sheet

 

Instruction manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs

 

 

275:
True RMS AC/DC Amps

AC Amps     
...400
DC Amps
...
400
Frequency    
...40 MHz
Capacitance
...4,000 uF
Temperature
...
1,000 F
AC Volts
...
600         
DC Volts
...600
Resistance
...40 Meg Ohm
Basic DC accuracy
...
0.5%
  • True RMS 400 A AC/DC
  • Measure motor in-rush current and run current
  • Measure temperature differential with relative mode
  • Non-contact voltage (NCV) feature to see if power is being supplied to the 24 VAC control circuit
  • Up to 4,000 microfarads to test motor start and run capacitors
  • Frequency, Min/Max/Record, Data Hold, and Peak Hold
  • 11,000 count display with 41 segment analog bargraph
  • CAT III 600V rated
  • cULus 61010
  • 3-year limited warranty

Product Sheet

 

Instruction manual

 

Specifications

 

Applications

 

FAQs



291:
700 AC Amps

AC Amps
...700
AC Volts
...600
DC Volts
...
600
Resistance
...
4,000 hm 
Basic DC accuracy
...0.75%
  • Peak hold function
  • Resistance
  • Audible continuity
  • 400 VDC
  • CAT III 600V rated
  • cULus 61010
  • 3-year limited warranty

Product Sheet

 

Instruction manual

 

Specifications

 

Applications

 

FAQs

293:
True RMS
700 AC Amps

AC Amps
...700
AC Volts
...
600
DC Volts
...
600
Frequency
...40 MHz
Resistance
...
40 Meg Ohm
Basic DC accuracy
...0.75%
  • Combine the first two bullets into one: True RMS, 700 A AC
  • Last bullet needs to be a cULus statement.  We’ll need to go over the exact wording with Corvin.
  • CAT III 600V rated
  • cULus 61010
  • 3-year limited warranty

Product Sheet

 

Instruction manual

 

Specifications

 

Applications

 

FAQs

296:
True RMS
700 AC/DC amps

AC Amps
...700
DC Amps
...700
AC Volts
...600
DC Volts
...600
Frequency
...40 MHz
Resistance
...40 Meg Ohm
Basic DC accuracy
...0.75%
  • First bullet needs to be: True RMS, 700 A AC/DC
  • Last bullet needs to be a cULus statement.  We’ll need to go over the exact wording with Corvin.
  • Delete the first two bullets (700 A AC/DC and True RMS)
  • Delete “Measure AC amps”.
  • Delete “DC amp measurements up to 700 A”
  • CAT III 600V rated
  • cULus 61010
  • 3-year limited warranty

Product Sheet

 

Instruction manual

 

Specifications

 

Applications

 

FAQs