Model
|
Measurement
Range |
Feature/Benefits |
Additional
Info |
265:

|
AC Amps
... 400
Frequency
... 40 MHz
Capacitance
... 4,000 uF
AC Volts
... 600
DC Volts
... 600
Resistance
...40 Meg Ohm
Basic DC accuracy
...0.5% |
- Slim jaw and body design for use is crowded electrical panels.
- Capacitance up to 4,000 micro-farads
- Frequency
- Up to 400 AC amps with 0.01 resolution
- AC/DC volts up to 600
- 0.1 DC millivolt resolution
- Diode, resistance, and audible continuity
- CAT III 600V rated
- cULus 61010
- 3-year limited warranty
|
Product Sheet
Instruction manual
Specifications
Applications
FAQs

|
270:

|
AC Amps
...400
Frequency
...400 MHz
Capacitance
...4,000 uF
Temperature
...1,000 F
AC Volts
... 600
DC Volts
...600
Resistance
... 40 Meg Ohm
Basic DC accuracy
... 0.5% |
- True RMS 400 A AC
- Measure motor in-rush current and run current
- Measure temperature differential with relative mode
- Frequency, Min/Max/Record, Data Hold, and Peak Hold
- Up to 40,000 microfarads to test start and run capacitors
- 4,000 count display with 41 segment analog bar graph
- CAT III 600V rated
- cULus 61010
- 3-year limited warranty
|
Product Sheet
Instruction manual
Specifications
Applications
Tech Tips
FAQs

|
275:
True RMS AC/DC Amps

|
AC Amps
...400
DC Amps
...400
Frequency
...40 MHz
Capacitance
...4,000 uF
Temperature
...1,000 F
AC Volts
...600
DC Volts
...600
Resistance
...40 Meg Ohm
Basic DC accuracy
...0.5% |
- True RMS 400 A AC/DC
- Measure motor in-rush current and run current
- Measure temperature differential with relative mode
- Non-contact voltage (NCV) feature to see if power is being supplied to the 24 VAC control circuit
- Up to 4,000 microfarads to test motor start and run capacitors
- Frequency, Min/Max/Record, Data Hold, and Peak Hold
- 11,000 count display with 41 segment analog bargraph
- CAT III 600V rated
- cULus 61010
- 3-year limited warranty
|
Product Sheet
Instruction manual
Specifications
Applications
FAQs


|
291:
700 AC Amps
|
AC Amps
...700
AC Volts
...600
DC Volts
...600
Resistance
...4,000 hm
Basic DC accuracy
...0.75% |
- Peak hold function
- Resistance
- Audible continuity
- 400 VDC
- CAT III 600V rated
- cULus 61010
- 3-year limited warranty
|
Product Sheet
Instruction manual
Specifications
Applications
FAQs

|
293:
True RMS
700 AC Amps
|
AC Amps
...700
AC Volts
...600
DC Volts
...600
Frequency
...40 MHz
Resistance
...40 Meg Ohm
Basic DC accuracy
...0.75% |
- Combine the first two bullets into one: True RMS, 700 A AC
- Last bullet needs to be a cULus statement. We’ll need to go over the exact wording with Corvin.
- CAT III 600V rated
- cULus 61010
- 3-year limited warranty
|
Product Sheet
Instruction manual
Specifications
Applications
FAQs

|
296:
True RMS
700 AC/DC amps
 |
AC Amps
...700
DC Amps
...700
AC Volts
...600
DC Volts
...600
Frequency
...40 MHz
Resistance
...40 Meg Ohm
Basic DC accuracy
...0.75% |
- First bullet needs to be: True RMS, 700 A AC/DC
- Last bullet needs to be a cULus statement. We’ll need to go over the exact wording with Corvin.
- Delete the first two bullets (700 A AC/DC and True RMS)
- Delete “Measure AC amps”.
- Delete “DC amp measurements up to 700 A”
- CAT III 600V rated
- cULus 61010
- 3-year limited warranty
|
Product Sheet
Instruction manual
Specifications
Applications
FAQs

|