Test Products International

Multimeters (DMMs)

 

 

 

 


TPI offers Digital Multimeters to fit a wide range of applications including electrical, electronic, commercial, HVAC/R, and industrial.



Model

Description

Additional
Info

460:
The 460 hand held oscilloscope features a 3” x 3” cold cathode fluorescent display providing test data in a clear easy to see format. The cursor readout function allows the width and amplitude of a signal to be measured precisely instead of trying to figure it out manually.
  • 4,000 count true RMS DMM, CACV, DCV ohms and continuity buzzer need optional adapters for current measurement
  • 20 MHz Bandwidth
  • Cursor Readout
  • Decibels
  • Pre and Post Triggering
  • Trend Mode
  • Dual Input
  • Real Time Sample Rate
  • Bright LCD Backlight
  • Optically Isolated RS232 Output
  • Continuous Autoset

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at

440:
The hand held 440 scope plus features an easy to use combination of a single input 1 MHz oscilloscope with True RMS DMM.
  • True RMS Auto Ranging DMM offers increased accuracy over average responding multimeters
  • 1MHz Oscilloscope can be used to view power signals to determine quality as well as correct amplitude and frequency, assisting in finding and preventing problems
  • Trend Mode enables surges and dropouts to be graphed.
  • Communication to a PC using optional RS-232 cable and software

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at


 

196:
0-24 mA output built in for process loop calibration, 0.05% accuracy, 50,000 counts, DMM with separate fuse and battery compartment
  • Process DMM with 0 to 24mA output
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV; max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; max resolution 0.01uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



194:
CAT IV 600 ACV, data logging, 0.05% accuracy, 50,000 count, True RMS DMM with separate fuse and battery compartment
  • Data logging
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • True RMS
  • Inductance
  • Frequency
  • Capacitance
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV: max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; resolution 0.01 uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment

Data Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at

126

192:
Data logging, 0.05% accuracy, 50,000 count, True RMS DMM with separate fuse and battery compartment.
  • Data logging
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • True RMS
  • Inductance
  • Frequency
  • Capacitance
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV: max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; resolution 0.01 uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment

Product Sheet

 

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at

126

183A:
True RMS DMM with temperature, capacitance, duty cycle, & low-pass filter
• 4,000 count
• True RMS for more accurate measurements
• Auto/manual ranging
• Temperature measurement
• Duty cycle to measure the amount of time the motor is on
• Low pass filter for noisy environments
• Separate fuse (2) and battery compartment
• Auto power off
• IR serial interface
Applications
• Test run and start capacitors
• Measure ambient and duct temp.
• Test control (thermostat, thermocouple, flame safety) and line voltages
• Measure resistance and test for continuity
• Line current up to 10 amps (in series)

Data Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs

163:
Full size DMM with analog bar graph; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
  • 3260 count display
  • 0.5% DCV basic accuracy
  • 0 to 750 ACV; max resolution 1mV
  • 0 to 1,000 DCV; max resolution 0.1mV
  • 0 to 32.6MΩ; max resolution 0.1Ω
  • Audible continuity
  • 0 to 10 amps AC/DC; max resolution 0.1uA
  • Analog bar graph
  • Data hold
  • Sleep mode/auto off

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs

153:
Full size, autoranging, easy to read, 0.3% DCV basic accuracy DMM; 1,000 DC volts and 750 AC volts
  • 0.3% DCV basic accuracy
  • 0 to 750 ACV; max resolution 1mV
  • 0 to 1,000 DCV: max resolution 0.1mV
  • 0 to 40MΩ; max resolution 0.1Ω
  • AC/DC amps to 10; max resolution 0.1uA
  • Min/Max
  • Data hold
  • Sleep mode/auto off

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at

126

135:

Full size DMM with capacitance; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
  • 4,000 count display
  • 0.5% DCV basic accuracy
  • 0 to 750 ACV; max resolution 0.1mV
  • 0 to 1,000 DCV; max resolution 0.1mV
  • 0 to 40MΩ; max resolution 0.1Ω
  • 0 to 10 amps AC/DC; 0.1uA resolution
  • Data hold

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs

133:

Large easy to read display in full size DMM; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
  • Large easy to read 2,000 count display
  • 0.5% DCV basic accuracy
  • 0 to 750 ACV; max resolution 1mV
  • 0 to 1,000 DCV; max resolution 0.1mV
  • 0 to 20MΩ; max resolution 0.1Ω
  • 0 to 10 amps AC/DC; max resolution 0.1uA
  • Data hold

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



126:
Compact autoranging DMM with 0.3% DCV basic accuracy and 400mA AC/DC range
  • 4,000 count display
  • 0.3% DCV basic accuracy
  • 0 to 600 volts AC/DC; max resolution 0.1V
  • 0 to 40MΩ resistance; max resolution 0.1Ω
  • Audible continuity
  • 0 to 400 mA amps AC/DC; max resolution 0.01mA
  • Autoranging
  • Min/Max
  • Data Hold
  • Sleep mode/auto off

Product Sheet

 

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at

126

122:

Compact DMM with adapter range for optional accessories, 0.5% DCV basic accuracy
  • 2,000 mvDC (2 DCV) adapter range
  • 2,000 count display
  • 0 to 600 volts AC and DC
  • 0 to 2,000 ohms
  • Audible continuity
  • 10 MOHM internal impedance
  • 0.5 % DCV basic accuracy

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs

120:

Compact, manual ranging, basic DCV 0.5% accuracy DMM
  • 2,000 count display
  • 0 to 600 volts AC and DC
  • 0 to 2,000 ohms
  • Audible continuity
  • 10 MOHM internal impedance
  • 0.5% DCV basic accuracy

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs

100:

No more guessing what range to switch your meter to — the TPI 100 does it automatically!
  • Automatically switches between ACV, DCV, and ohms (resistance). Benefit Simple to use. Meter selects function and range, just connect the leads to the device under test.
  • Single button operation. Benefit EZ to use. Enables users with limited knowledge to perform tests safely.
  • 0 to 600 volts AC and DC Benefit Enough range to safely perform measurements
  • 10 MΩ internal impedance. Benefit High impedance prevents inaccurate reading caused by circuit loading.
    Auto power off. Benefit Increases battery life by turning off the multimeter when not in use.
  • 4,000 count display
  • Up to 40MΩ

Product Sheet

Instruction Manual

Specifications

Applications

Tech Tips

FAQs