Model
|
Description |
Additional
Info |
460:
 |
The 460 hand held oscilloscope features a 3” x 3” cold cathode fluorescent display providing test data in a clear easy to see format. The cursor readout function allows the width and amplitude of a signal to be measured precisely instead of trying to figure it out manually.
- 4,000 count true RMS DMM, CACV, DCV ohms and continuity buzzer need optional adapters for current measurement
- 20 MHz Bandwidth
- Cursor Readout
- Decibels
- Pre and Post Triggering
- Trend Mode
- Dual Input
- Real Time Sample Rate
- Bright LCD Backlight
- Optically Isolated RS232 Output
- Continuous Autoset
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

Check inventory status at

|
440:
 |
The hand held 440 scope plus features an easy to use combination of a single input 1 MHz oscilloscope with True RMS DMM.
- True RMS Auto Ranging DMM offers increased accuracy over average responding multimeters
- 1MHz Oscilloscope can be used to view power signals to determine quality as well as correct amplitude and frequency, assisting in finding and preventing problems
- Trend Mode enables surges and dropouts to be graphed.
- Communication to a PC using optional RS-232 cable and software
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

Check inventory status at

 |
196:
 |
0-24 mA output built in for process loop calibration, 0.05% accuracy, 50,000 counts, DMM with separate fuse and battery compartment
- Process DMM with 0 to 24mA output
- 50,000 count display
- 0.05% DCV basic accuracy
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV; max resolution 0.001mV
- 0 to 50MΩ; max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; max resolution 0.01uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs


|
194:
 |
CAT IV 600 ACV, data logging, 0.05% accuracy, 50,000 count, True RMS DMM with separate fuse and battery compartment
- Data logging
- 50,000 count display
- 0.05% DCV basic accuracy
- True RMS
- Inductance
- Frequency
- Capacitance
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV: max resolution 0.001mV
- 0 to 50MΩ; max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; resolution 0.01 uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

Check inventory status at

|
192:
 |
Data logging, 0.05% accuracy, 50,000 count, True RMS DMM with separate fuse and battery compartment.
- Data logging
- 50,000 count display
- 0.05% DCV basic accuracy
- True RMS
- Inductance
- Frequency
- Capacitance
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV: max resolution 0.001mV
- 0 to 50MΩ; max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; resolution 0.01 uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

Check inventory status at

|
183A:
 |
True RMS DMM with temperature, capacitance, duty cycle, & low-pass filter
• 4,000 count
• True RMS for more accurate measurements
• Auto/manual ranging
• Temperature measurement
• Duty cycle to measure the amount of time the
motor is on
• Low pass filter for noisy environments
• Separate battery and fuse compartment
• Auto power off
• IR serial interface
Applications
• Test run and start capacitors
• Measure ambient and duct temp.
• Test control (thermostat, thermocouple, flame
safety) and line voltages
• Measure resistance and test for continuity
• Line current up to 10 amps (in series) |
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
163:
 |
Full size DMM with analog bar graph; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
- 3260 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 32.6MΩ; max resolution 0.1Ω
- Audible continuity
- 0 to 10 amps AC/DC; max resolution 0.1uA
- Analog bar graph
- Data hold
- Sleep mode/auto off
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
153:
 |
Full size, autoranging, easy to read, 0.3% DCV basic accuracy DMM; 1,000 DC volts and 750 AC volts
- 0.3% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV: max resolution 0.1mV
- 0 to 40MΩ; max resolution 0.1Ω
- AC/DC amps to 10; max resolution 0.1uA
- Min/Max
- Data hold
- Sleep mode/auto off
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

Check inventory status at

|
135:
|
Full size DMM with capacitance; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
- 4,000 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 0.1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 40MΩ; max resolution 0.1Ω
- 0 to 10 amps AC/DC; 0.1uA resolution
- Data hold
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
133:
|
Large easy to read display in full size DMM; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
- Large easy to read 2,000 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 20MΩ; max resolution 0.1Ω
- 0 to 10 amps AC/DC; max resolution 0.1uA
- Data hold
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs


|
126:

|
Compact autoranging DMM with 0.3% DCV basic accuracy and 400mA AC/DC range
- 4,000 count display
- 0.3% DCV basic accuracy
- 0 to 600 volts AC/DC; max resolution 0.1V
- 0 to 40MΩ resistance; max resolution 0.1Ω
- Audible continuity
- 0 to 400 mA amps AC/DC; max resolution 0.01mA
- Autoranging
- Min/Max
- Data Hold
- Sleep mode/auto off
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

Check inventory status at

|
122:

|
Compact DMM with adapter range for optional accessories, 0.5% DCV basic accuracy
- 2,000 mvDC (2 DCV) adapter range
- 2,000 count display
- 0 to 600 volts AC and DC
- 0 to 2,000 ohms
- Audible continuity
- 10 MOHM internal impedance
- 0.5 % DCV basic accuracy
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
120:

|
Compact, manual ranging, basic DCV 0.5% accuracy DMM
- 2,000 count display
- 0 to 600 volts AC and DC
- 0 to 2,000 ohms
- Audible continuity
- 10 MOHM internal impedance
- 0.5% DCV basic accuracy
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
100:

|
No more guessing what range to switch your meter to — the TPI 100 does it automatically!
- Automatically switches between ACV, DCV, and ohms (resistance). Benefit Simple to use. Meter selects function and range, just connect the leads to the device under test.
- Single button operation.
Benefit EZ to use. Enables users with limited knowledge to perform tests safely.
- 0 to 600 volts AC and DC
Benefit Enough range to safely perform measurements
- 10 MΩ internal impedance.
Benefit High impedance prevents inaccurate reading caused by circuit loading.
Auto power off.
Benefit Increases battery life by turning off the multimeter when not in use.
- 4,000 count display
- Up to 40MΩ
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|