Test Products International

Multimeters (DMMs)

 

 

 

 


TPI offers Digital Multimeters to fit a wide range of applications including electrical, electronic, commercial, HVAC/R, and industrial.



Model

Description

Additional
Info

460:
The 460 hand held oscilloscope features a 3” x 3” cold cathode fluorescent display providing test data in a clear easy to see format. The cursor readout function allows the width and amplitude of a signal to be measured precisely instead of trying to figure it out manually.
  • 4,000 count true RMS DMM, CACV, DCV ohms and continuity buzzer need optional adapters for current measurement
  • 20 MHz Bandwidth
  • Cursor Readout
  • Decibels
  • Pre and Post Triggering
  • Trend Mode
  • Dual Input
  • Real Time Sample Rate
  • Bright LCD Backlight
  • Optically Isolated RS232 Output
  • Continuous Autoset
  • cULus 61010-1
  • CAT II - 1000V, CAT III - 600V
  • 3 Year Limited Warranty

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at

440:
The hand held 440 scope plus features an easy to use combination of a single input 1 MHz oscilloscope with True RMS DMM.
  • True RMS Auto Ranging DMM offers increased accuracy over average responding multimeters
  • 1MHz Oscilloscope can be used to view power signals to determine quality as well as correct amplitude and frequency, assisting in finding and preventing problems
  • Trend Mode enables surges and dropouts to be graphed.
  • Communication to a PC using optional RS-232 cable and software
  • cULus 61010-1
  • CAT II - 1000V, CAT III - 600V
  • 3 Year Limited Warranty

Product Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at


 

196:
0-24 mA output built in for process loop calibration, 0.05% accuracy, 50,000 counts, DMM with separate fuse and battery compartment
  • Process DMM with 0 to 24mA output
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV; max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; max resolution 0.01uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment
  • cULus 61010-1
  • CAT II-1000VDC, 750VAC, CATIII-600V
  • Limited Life time Warranty

Product Sheet

 

nstruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



194:
CAT IV 600 ACV, data logging, 0.05% accuracy, 50,000 count, True RMS DMM with separate fuse and battery compartment
  • Data logging
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • True RMS
  • Inductance
  • Frequency
  • Capacitance
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV: max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; resolution 0.01 uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment
  • cULus 61010-1
  • CATIII-1000VC, CATIII-1000V, CAT IV-600V, CAT III 1000V
  • Limited Life time Warranty

Data Sheet

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at

126

192:
Data logging, 0.05% accuracy, 50,000 count, True RMS DMM with separate fuse and battery compartment.
  • Data logging
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • True RMS
  • Inductance
  • Frequency
  • Capacitance
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV: max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; resolution 0.01 uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment
  • cULus 61010-1
  • CAT II-1000VDC, 750VAC, CAT III - 600V
  • Limited Life time Warranty

Product Sheet

 

Instruction Manual

 

Specifications

 

Applications

 

Tech Tips

 

FAQs



Check inventory status at

126

183A:
True RMS DMM with temperature, capacitance, duty cycle, & low-pass filter
  • 4,000 count
  • True RMS for more accurate measurements
  • Auto/manual ranging
  • Temperature measurement
  • Duty cycle to measure the amount of time the motor is on
  • Low pass filter for noisy environments
  • Separate fuse (2) and battery compartment
  • Auto power off
  • IR serial interface
  • cULus 61010-1
  • CAT II - 1000V, CAT III - 600V
  • 3 Year Limited Warranty
    Applications
  • Test run and start capacitors
  • Measure ambient and duct temp.
  • Test control (thermostat, thermocouple, flame safety) and line voltages
  • Measure resistance and test for continuity
  • Line current up to 10 amps (in series)
  • Data Sheet

    Instruction Manual

     

    Specifications

     

    Applications

     

    Tech Tips

     

    FAQs

    163:
    Full size DMM with analog bar graph; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
    • 3260 count display
    • 0.5% DCV basic accuracy
    • 0 to 750 ACV; max resolution 1mV
    • 0 to 1,000 DCV; max resolution 0.1mV
    • 0 to 32.6MΩ; max resolution 0.1Ω
    • Audible continuity
    • 0 to 10 amps AC/DC; max resolution 0.1uA
    • Analog bar graph
    • Data hold
    • Sleep mode/auto off
    • cULus 61010-1
    • CAT II - 1000V, CAT III - 600V
    • 3 Year Limited Warranty

    Product Sheet

    Instruction Manual

     

    Specifications

     

    Applications

     

    Tech Tips

     

    FAQs

    153:
    Full size, autoranging, easy to read, 0.3% DCV basic accuracy DMM; 1,000 DC volts and 750 AC volts
    • 0.3% DCV basic accuracy
    • 0 to 750 ACV; max resolution 1mV
    • 0 to 1,000 DCV: max resolution 0.1mV
    • 0 to 40MΩ; max resolution 0.1Ω
    • AC/DC amps to 10; max resolution 0.1uA
    • Min/Max
    • Data hold
    • Sleep mode/auto off
    • cULus 61010-1
    • CAT II - 1000V, CAT III - 600V
    • 3 Year Limited Warranty

    Product Sheet

    Instruction Manual

     

    Specifications

     

    Applications

     

    Tech Tips

     

    FAQs



    Check inventory status at

    126

    135:

    Full size DMM with capacitance; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
    • 4,000 count display
    • 0.5% DCV basic accuracy
    • 0 to 750 ACV; max resolution 0.1mV
    • 0 to 1,000 DCV; max resolution 0.1mV
    • 0 to 40MΩ; max resolution 0.1Ω
    • 0 to 10 amps AC/DC; 0.1uA resolution
    • Data hold
    • cULus 61010-1
    • CAT II - 1000V, CAT III - 600V
    • 3 Year Limited Warranty

    Product Sheet

    Instruction Manual

     

    Specifications

     

    Applications

     

    Tech Tips

     

    FAQs

    133:

    Large easy to read display in full size DMM; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
    • Large easy to read 2,000 count display
    • 0.5% DCV basic accuracy
    • 0 to 750 ACV; max resolution 1mV
    • 0 to 1,000 DCV; max resolution 0.1mV
    • 0 to 20MΩ; max resolution 0.1Ω
    • 0 to 10 amps AC/DC; max resolution 0.1uA
    • Data hold
    • cULus 61010-1
    • CAT II - 1000V, CAT III - 600V
    • 3 Year Limited Warranty

    Product Sheet

    Instruction Manual

     

    Specifications

     

    Applications

     

    Tech Tips

     

    FAQs



    126:
    Compact autoranging DMM with 0.3% DCV basic accuracy and 400mA AC/DC range
    • 4,000 count display
    • 0.3% DCV basic accuracy
    • 0 to 600 volts AC/DC; max resolution 0.1V
    • 0 to 40MΩ resistance; max resolution 0.1Ω
    • Audible continuity
    • 0 to 400 mA amps AC/DC; max resolution 0.01mA
    • Autoranging
    • Min/Max
    • Data Hold
    • Sleep mode/auto off
    • cULus 61010-1
    • CAT II - 1000V, CAT III - 600V
    • 3 Year Limited Warranty

    Product Sheet

     

    Instruction Manual

     

    Specifications

     

    Applications

     

    Tech Tips

     

    FAQs



    Check inventory status at

    126

    122:

    Compact DMM with adapter range for optional accessories, 0.5% DCV basic accuracy
    • 2,000 mvDC (2 DCV) adapter range
    • 2,000 count display
    • 0 to 600 volts AC and DC
    • 0 to 2,000 ohms
    • Audible continuity
    • 10 MOHM internal impedance
    • 0.5 % DCV basic accuracy
    • cULus 61010-1
    • CAT II - 1000V, CAT III - 600V
    • 3 Year Limited Warranty

    Product Sheet

    Instruction Manual

     

    Specifications

     

    Applications

     

    Tech Tips

     

    FAQs

    120:

    Compact, manual ranging, basic DCV 0.5% accuracy DMM
    • 2,000 count display
    • 0 to 600 volts AC and DC
    • 0 to 2,000 ohms
    • Audible continuity
    • 10 MOHM internal impedance
    • 0.5% DCV basic accuracy
    • cULus 61010-1
    • CAT II - 1000V, CAT III - 600V
    • 3 Year Limited Warranty

    Product Sheet

    Instruction Manual

     

    Specifications

     

    Applications

     

    Tech Tips

     

    FAQs

    100:

    No more guessing what range to switch your meter to — the TPI 100 does it automatically!
    • Automatically switches between ACV, DCV, and ohms (resistance). Benefit Simple to use. Meter selects function and range, just connect the leads to the device under test.
    • Single button operation. Benefit EZ to use. Enables users with limited knowledge to perform tests safely.
    • 0 to 600 volts AC and DC Benefit Enough range to safely perform measurements
    • 10 MΩ internal impedance. Benefit High impedance prevents inaccurate reading caused by circuit loading.
    • Auto power off. Benefit Increases battery life by turning off the multimeter when not in use.
    • 4,000 count display
    • Up to 40MΩ
    • cULus 61010-1
    • CAT II 1,000-V / CATIII 600V
    • 3 Year Limited Warranty

    Product Sheet

    Instruction Manual

    Specifications

    Applications

    Tech Tips

    FAQs