TPI contact temperature testers are accurate, reliable, and built to last. Models 341K, 343 and 367D can be auto field calibrated to system accuracy (tester plus probe) of +/- 1°F in less than 10 seconds in ice water.
AUTO FIELD CALIBRATION Perform ice bath calibration to achieve ±1°F system accuracy within the 30°F to 120°F temperature range. Calibration is an easy two-step process performed with instrument keypad, no additional tools needed.
Model |
Description |
Additional |
|---|---|---|
340: |
340: -40 to +1,200 °F range, single button operation, uses K-type thermocouple with sub-mini connector • 340 includes: 340 temperature tester, A304 tilt stand protective boot, GK12M temperature probe, A340 soft pouch, batteries, and instruction manual. |
View temperature probes that can be used with the 340: |
341K: |
341K: -58 to 2,462 °F (-50 to 2,462 °C) range; Auto Field Calibrate to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; C/F; Min-Max and hold features, uses K-type thermocouple with sub-mini connector • 341K: Single Input K-Type Thermocouple with A304 protective boot, A255 soft pouch, and no temperature probes • 341KC1: Single Input K-Type Thermocouple Thermometer with GK11M Probe, A304 protective boot, A255 soft pouch • 341KC2: Single Input K-Type Thermocouple Thermometer with GK13M Probe, A304 protective boot, A255 soft pouch |
View temperature probes that can be used with the 341K: |
343:
|
343: -58 to 2,462 °F (-50 to 2,462 °C) range; Auto Field Calibrate to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; C/F; Min-Max and hold features, uses K-type thermocouple with sub-mini connector • 343C1: Dual Input K-Type Thermocouple Thermometer with two GK11M Probes, A304 protective boot, A255 soft pouch • 343C2: Dual Input K-Type Thermocouple Thermometer with two GK13M Probes, A304 Rubber Boot, A255 Soft Carrying Case • 343C3: Dual Input K-Type Thermocouple Thermometer with two CK21M pipe clamp probes, two GK13M Probes, and A908 Case |
View temperature probes that can be used with the 343: • K-Type Sub-Mini |
351: |
351: -40 to 220°F range
(351X = -40 to 104°C) +/- 1 °F system accuracy (tester and probe) over 32 to 158°F range, single button, thermistor probe with bipolar connector • 351/F1: Thermistor Thermometer with FX11B Probe, A304 protective boot, A255 soft pouch |
View temperature probes that can be used with the 351: |
353: |
353: -40 to 220°F range +/- 1°F accuracy (thermistor), -328°F to 750°F range 0.3% basic accuracy (T-type thermocouple), single button operation, uses thermistor probe or T-type thermocouple with Lumberg connector • 353: 353, A304 protective boot, A255 soft pouch, and no temperature probes |
View temperature probes that can be used with the 353: |
354: ![]() |
354: -40 to 220°F range +/- 1.8°F accuracy (thermistor), -328°F to 750°F range 0.3% basic accuracy (T-type thermocouple), Min/Max Record, °C/°F Selectable, uses thermistor probe or T-type thermocouple with Lumberg connector • 354: 354, A304 protective boot, A255 soft pouch, and no temperature probes |
View temperature probes that can be used with the 354: |
365: ![]() |
365: -328°F to 1112°F (-200°C to 600°C) range0.1% basic tester accuracy, waterproof IP67, uses K-type thermocouple with sub-mini connector • 365: 365, no temperature probes |
View temperature probes that can be used with the 365: |
367D: |
367D: -58°F to 302°F (-50°C to 150°C) range (thermistor), -328°F to 1112°F (-200°C to 600°C) range (K-type thermocouple), -328°F to 752°F (-200°C to 400°C) range (T-type thermocouple), Auto Field Calibrated to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; uses Thermistor, K-type, or T-type probes with Lumberg connectors, stores 16 readings, optional data logging software and accessories to data log 16,000 readings with sample interval from 1 second to 24 hours. • 367D: 367D, NO temperature probes Data logging interface and software (A367) sold separately |
View temperature probes that can be used with the 367D: |