The TPI Model 716 Combustion Analyzer is a state of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion.
- Built-in differential manometer with 0.001” H2O resolution
- Calculates combustion efficiency
- Data Logging with time and date stamp
- Will not shut off if 15 ppm CO is present for increased safety
- Communicate to a PC via the USB interface
- Optional A740 IR printer available for hard copies of test results
- Built-in differential thermometer
- Push on fittings for fast and easy use
- New! Optional Bluetooth interface
Quick and Simple Setup
All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selectionduring start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need toperform fuel selection every time the analyzer is turned on.
The TPI 716 Flue Gas Analyzer comes complete with the following standard accessories:
( ) Denotes part number
- TPI 716 Analyzer
- Combustible Gase Leak Probe (A806)
- Rubber Boot (A765) 1 each installed on analyzer
- Soft Carrying Case (A768) – 1 each
- Flue Sampling Probe (A770) – 1 each
- In-Line Filter / Water Trap installed on Flue probe (A796) – 1 each
- Disc water filter installed in water trap (A794W) – 1 each
- Temperature Probe (GK11M) – 1 each
- Battery Charger (A766) – 1 each
- Mini Pump Protection Filter Assembly (A763) – 1 each
- Exhaust Spigot Removable (A764) – 1 each
- Pressure Tubing (A774) – 1 each 6’ piece
- Static Pressure Tips (A776) – 2 each
- 1/4” barbed to 1/8” NPT fitting (A603) – 2 each
- Gas Valve Adapter (A611) – 1 each
- Instruction Manual
The TPI 716 Flue Gas Analyzer has the following options available:
- A807 PC Software and cable for communication to a PC.
- A740 infrared printer (Included with 716A740)
Model 716 Features
Using TPI analyzers to determine combustion efficiency at the time of equipment set up minimizes call backs and can be used to verify to the home owner the value of service work by showing the increase in equipment efficiency after work is performed. Efficiency calculation can also be used to generate business by demonstrating the need to improve the efficiency of equipment or to show the benefit of purchasing new equipment with higher efficiency.
- Built-in differential manometer with 0.001” H2O resolution
- Calculates combustion efficiency
- Data Logging with time and date stamp
- Will not shut off if 15 ppm CO is present for increased safety
- Communicate to a PC via the USB interface
- Optional A740 IR printer available for hard copies of test results
- Built-in differential thermometer
- Store function to save up to 10 readings
- Pump driven for fast response
- Push on fittings for fast and easy use
- Large easy to read backlit display
- Ten selectable fuels
Model 716 Specifications | ||
---|---|---|
Instrument | ||
Operating Temperature Range | 14°F to +122°F (-10°C to +50°C) | |
Battery / Batery Life | Rechargeable Ni-MH / > 6 Hours | |
Charger Input Voltage | 115V or 230V : 50/60 Hz AC | |
Fuels | Natural Gas, LPG, Light Oil, Heavy
Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse |
|
Pressure Ranges | mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O | |
Display | Backlit Graphic LCD | |
Data Storage | 100 sets of readings, multiple pages | |
Time and Date | 24 Hour Real Time Clock | |
Dimensions | 7.8” (200mm) x 3.5” (90mm) x 2.4” (60mm) | |
Weight | 1.1lbs (500g) | |
Conforms to | EN50379 |
Flue Temperature Probe | ||
---|---|---|
Construction | Pistol Grip with Stainless Steel Shaft | |
Hose Length | 8.2’ (2500mm) | |
Insertion Length | 7.9” (200mm) | |
'K' Type Thermocouple Accuracy | +/- 0.3% of fullscale, +/- 2°F (1°C) | |
Maximum Temperature | 1472°F (800°C) |
Gases | Range | Resolution | Accuracy |
Oxygen | 0-25% | 0.1% | +/- 0.3% |
Carbon Monoxide (low) | 0-10,000 ppm | 1 ppm | (<100ppm) +/- 5 ppm (>=100ppm) +/- 5% |
Carbon Monoxide (high) | 0-100,000 ppm | 0.001% | >10,000ppm: +/- 10% |
Nitric Oxide * | 0-5000ppm | 1 ppm | +/- 5ppm (<100ppm) +/- 5% (<1000ppm) +/- 10% (>1000ppm) |
Carbon Dioxide | 0-25% | 0.1% | Calculated |
CO/CO2 Ratio | 0-0.999 | 0.001 | Calculated |
Combustion Efficiency | 0-100% | 0.1% | Calculated |
Gas Leak Sensor | 100-10,000ppm (calibrated to methane) |
* if fitted
Pressure Measurement | ||
---|---|---|
Selectable Ranges | mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O | |
Range | - 100 mbar to + 100 mbar -10 kPa to + 10 kPa -40 inH2O to 40 inH2O |
|
Resolution | 0.001 mbar (0~9.999 mbar) 0.01 mbar (10.00~99.99 mbar) |
|
Accuracy | < 5 mbar: +/- 0.05 mbar > 5 mbar: +/- 1% of reading |
Temperature Measurement | ||
---|---|---|
Input Type | K-Type thermocouple | |
Range | -58°F to 2372°F (-50°C to 1300°C)* | |
Resolution | 1°F (1°C) | |
Accuracy | +/- (0.3% of rdg + 2°F) or +/- (0.3% of rdg + 1°C) |
Frequently Asked Questions
When should I use the optional A773 oil filter?
If your analyzer is used in an oil fuel application the A773 filter should be used. This filter does not have to be removed for other fuel types.
Should I set my analyzer to net or gross efficiency?
Gross efficiency is the correct choice for applications in the United States.
Can I use any of the TPI analyzers to test for the presence of combustible gas in the flue?
Yes, the 712 has the ability to test for combustible gases in the flue.
Can I log and send test data to a computer?
Yes, the 712 and 714 have the ability to communicate to a computer by using the optional A767 infrared adapter.
Can I test for CO in ambient air?
Yes, the 708, 709, 712, and 714 can all test for carbon monoxide in ambient air.
Do any of the TPI analyzers have a built in manometer?
Yes, the 709, 712, and 714 have built in differential manometers.
Product Documentation