Use the MFT5010 to test five major electrical testing requirements including insulation resistance, continuity, loop impedance and RCCB, as well as earth resistance.

Additionally, the MFT5010’s Phase indicator can check a wide range of 3-Phase Power sources from 110V to 600V.
Features:
- Continuity Test: Live circuit warning beeps and “LIVE” displays on the LCD
- Insulation Resistance
- Loop impedance: Displays main voltage on the LCD, indicates Phase Angle on the LCD, with automatic overheat protection
- PSC (Prospective Short-Circuit Current)
- RCD test: Displays main voltage and Phase Angle on the LCD
- AC and DC Voltage
- Earth Resistance: 3 or 2 pole measurement
Setting the standard for multifunction test equipment, the MFT5010 can be used to test a very wide range of requirements including insulation resistance, continuity, loop impedance and RCCB, and earth resistance, in addition to Phase indication.

| Model MFT5010 Specifications | ||
|---|---|---|
| Continuity Resistance Ranges (EN61557-4) | ||
| Measuring Ranges | 20.00Ω / 200.0Ω | |
| Open Circuit Voltage | 4V DC min. | |
| Short Circuit Current | 200mA DC min. in 20Ω Range | |
| Accuracy | ±3% rdg. ±3dgt. ±0.1Ω | |
| Number of Measurements | 1000 Times | |
| Insulation Resistance Range(Riso) (EN61557-2) | ||
| Test Voltage | 250V/500V/1000V | |
| Output Voltage Open Circuit | 250V±10% / 500V ±10% / 1000V±10% | |
| Output Current | 1mA DC at 0.25MΩ(250V) 1mA DC at 0.5MΩ(500V) 1mA DC at 1MΩ(1000V) |
|
| Output Short Circuit Current | 1.3mA approx. | |
| Measuring Ranges | 20.00MΩ/200.0MΩ/2000MΩ | |
| Accuracy | (20MΩ) ±3% of rdg. ±5dgt. (200MΩ) ±3% of rdg. ±10dgt. (1000MΩ) ±3% of rdg. ±20dgt. (2000MΩ) ±3% of rdg. ±40dgt. |
|
| Number of Measurements | 2000 Times | |
| Loop Impedence Range(Rs) (EN61557-3) | ||
| Rated Voltage | 230V AC ±10% | |
| AC Voltage Measuring Range | MAX 253V AC | |
| Test Current (at AC230V) | 20Ω Range 23A approx. 200Ω Range 2.3A approx. 2000Ω Range 0.23A approx. |
|
| Test Period | Half Cycle of AC | |
| Accuracy (at AC230V) | 20Ω ±3% of rdg. ±5dgt. ±0.1Ω 200Ω ±3% of rdg. ±5dgt. 2000Ω ±3% of rdg. ±5dgt. |
|
| Over Temperature Indication | 'Hot' on the LCD | |
| PSC (Prospective Short-Circuit Current) (EN61557-3) | ||
| Rated Voltage | 230V AC ±10% | |
| AC Voltage Measuring Range | MAX 253V AC | |
| Test Current (at AC230V) | 23A approx. | |
| Test Period | Half Cycle of AC | |
| PSC Data Collection | LINE VOLTAGE/LOOP IMPEDANCE | |
| Over Temperature Indication | 'Hot' on the LCD | |
| RCD Ranges (EN61557-6) | ||
| Rated Voltage | 230V AC ±10% | |
| AC Voltage Measuring Range | MAX 253V AC | |
| Trip Current Setting (at AC230V) | 10/30/100/300/500mA | |
| Test Current Factor | X1/2, X1, X5 | |
| Trip Time Duration | 2000msec. | |
| Earth Leakage Current | Less than 1mA | |
| Accuracy (at AC230V) | Trip Current ±3% of Test Curent at 230V Trip Time ±3% rdg. ±3dgt. +1ms ACV ±3% rdg. ±5dgt. |
|
| Over Temperature Indication | 'Hot' on the LCD | |
| AC Voltage Ranges | ||
| Measuring Ranges | 200V/600V | |
| Input Impedance | Approx. 10MΩ | |
| Input Frequency | 45Hz - 450Hz | |
| Accuracy | ±3% rdg. ±5dgt. | |
| DC Voltage Ranges | ||
| Measuring Ranges | 200V/1000V | |
| Input Impedance | Approx. 10MΩ | |
| Accuracy | ±3% rdg. ±3dgt. | |
| Earth Resistance Ranges (EN61557-5) | ||
| Measuring Ranges | 20Ω/200Ω/2000Ω | |
| Test Waveform | Approx. 570Hz AC / Less Than 50V RMS | |
| Accuracy | 20Ω ±3% rdg. ±5dgt. ±0.1Ω 200Ω/2000Ω ±3% rdg. ±5dgt. |
|
| General Specifications | ||
| Operating Temperature | 0°C - 40°C | |
| Storage Temperature | -10° - 50°C | |
| Operating Humidity | 70% max. | |
| Storage Humidity | 80% max. | |
| Dimensions | 170 X 210 X 90mm | Weight | 3Kg |
| Fuse Protection | ||
| (0.5A/600V/fast blow) | Continuity/Insulation/Earth Range | |
| (6.3A.250V/delay blow) | Loop RCD Ranges | |
| Power Supply | 8 X 1.5V Battery (AA or R-6) | |
| Battery Life | 100 Hours | |
| Number of Measurements | 2000 Times | |
Coming soon!
Product Documentation![]()
Click below to view or download product documentation PDFs: